Test station for checking personnel grounding connection of wrist straps and footwear, according to the IEC 61340-5-1.
- Separate testing of left and right shoe; the test is executed at 50V or 100V to provide more accuracy.
- A relay output allows access to ESD Protected Area.
- Internal battery supplied 9V or external 9V DC.
- ISO9000 traceable certificate is included.
- High efficiency led displays.
- Fully programmable by keyboard.
Complete test station Including:
Wristlab-II Tester
floor mats for shoes control
Yellow panel mount
Support column
WRISTLAB II TESTER WITHOUT ACCESSORIES :

Test station for simultaneous verification of a correct grounding of the operator's wristband and footwear in accordance with IEC 61340-5-1.
The measurement of the shoes is done independently for the left foot and for the right foot; the test is carried out under 50V or 100V for a more precise measurement
By means of an internal relay it is possible to allow access to the EPA zone.
- Power supply: 9V internal battery, or 9Vdc in external power supply.
- ISO9000 traceable calibration certificate included.
The test station can work in 4 modes :
1) Simultaneous measurement of the bracelet and shoes
2) Measurement of the single bracelet
3) Measuring shoes only
4) HandsFree mode (without the need to press any key, if the shoe measurement in series passes the test the internal relay will trip and entry into the EPA zone is allowed)
High performance LED display.
- Wrist strap: 0 - 750 Kohm
- High bracelet strap: 35 Mohm
- Boot Low Limit: 0 - 100 Kohm
- High shoes limit: 35 - 70 - 100 Mohm