Single workstation continuous monitor, Meets ANSI/ESD S20.20 in accordance with ESD TR1.0-01-01.
- Continuously monitors 2 operator dual-wire wrist straps and 1 worksurface mat: Visible and audible alarms indicate improper grounding of the operator and worksurface.
- Adjustable operator test voltage and upper limit: Test voltage can be set to 9 or 16 volts; test limit can be set to 10 or 35 megohms.
- Adjustable audible alarm: Buzzer volume may be disabled or set to loud or soft.
- Simple installation and setup: Mounting hardware and wire management clips are included.
- Power adapter not included: power adapter sold separately for European and UK outlets. (752 09046)
- NIST Calibrated: Calibrated with accepted procedures and standards traceable to the National Institute of Standards and Technology.
Specifications
- Power adapter output plug:
- polarization: Center negative
- Dimensions: 5.5 mm O.D. x 2.1 mm I.D. x 9.5 mm Length
- Operating temperature: 10 to 43°C (50 to 110°F)
- Environmental requirements:
- Indoor use only
- Maximum relative humidity: 80% for temperatures up to 31°C to 50% relative humidity at 40°C.
- Operator test voltages (open circuit, typical value):
- Operator test current: < 3 microamps (typical value)
- Operator test limits (+-15%):
- 1.5 megohms to 10 megohms (default)
- 1.5 megohms to 35 megohms
- Worksurface test limit: 3.7 megohms (+-10%)
- Dimensions
- Monitor: 165 x 79 x 35 mm (6.5" x 3.125" x 1.375")
- Operator remote: 70 x 25 x 25 mm (2.75" x 1.0" x 1.0")
- Certifications: cULus, CE, UKCA
- Country of origin: United States of America