Compact stand-alone high-precision temperature measurement device for quick and accurate temperature measurement.
The WCU unit is strategically designed for users that need to measure fast and easy, while maintaining the highest level of accuracy.
It comes with a large, non-backlite display.
Quick and accurate temperature measurements.
Intuitive navigation
Digital display for fast temperature unit change between °C and °F, and other functionalities. Values are easily readable from the large non-backlite display.
Fast and easy measurement
Effortlessly auto-calibrate in less than 10 seconds, ensuring the operator can focus on the important soldering task with a precise temperature for best productivity.
The Auto-Calibration function can be used with: WX 1, WX 2, WXD 2, WXA 2, WXR 3, WXsmart.
Note: For the Auto-Calibration function a RS 232 cable (order number: 810 87647 10) needs to be purchased separately.
High-mobility
The compact designed, battery-powered Weller High Precision Temperature Measurement Device can easily be shared between different workstations.
Simultaneous use of thermocross and thermocouple
Keep track of soldering tip and soldering bath temperatures simultaneously.
Temperature measurement count function
Number of tip temperature measurement will be automatically counted. This function can be useful for control of changing sensor.
Max hold function
The WCU display will show/hold the maximum temperature measured.
Low energy consumption
Auto Turn-off Timer saves battery life shutting down the unit's power after 10 mins without use.
Different grounding possibilities, ex works = hard grounding.
ESD sage
The Weller WCU Temperature Measurement Device is fully ESD safe.
Technical Data
- Temperature measuring range Thermocross: 0-400°C (32-752°F)
- Temperature measuring range Type-K/Thermocouple: 150-1200°C (302°F-2192°F)
- Applicable sensor: K (CA) type thermocouple
- Measuring tolerance: +-3°C (between 300 and 600°C) +-6°F (between 572 and 1112°F)
- Energy supply: 9V Dry battery Alkaline cell recommended. Recommended battery Ansmann XPower alkaline battery 9V E-block.
- Dimensions (L x W x H): 138 x 73 x 43mm
- Weight: 120g (Without battery)
- Ambient temperature: 0°C - 40°C
- Air humidity range: max. 80% Relative air humidity, without condensation.
- Ambient conditions: Applicable pollution degree 2 (According to IEC/ UL61010-1)